改进食品中过氧化值测定效率的研究

  • 打印
  • 收藏
收藏成功


打开文本图片集

中图分类号:TS207 文献标志码:A 文章编号:1674-0270(2025)36-0142-04

Abstract:To address the issues ofcumbersome operation and long processing time in the first method (indicator titrationmethod)ofGB50o9.227—2023 "NationalFoodSafetyStandard-Determinationof PeroxideValueinFods", the study conducts optimization research on three key steps: sample pretreatment,reaction process,and titration operation,strictlyadheringto the technical requirementsofthenationalstandard.Byreplacing traditionaloperation equipment with a high-throughput vacuum paralelconcentrator,a constant-temperature water bath shaker under light avoidance,andanautomatictitrator,aneficientdeterminationmethod isestablishedandcompared withthetraditional nationalstandardmethodinermsofefciency,accuracyandprecision.Theresultsshowthattheimprovedmethodcan significantly reduce the detection time, with the efficiency of a single sample determination increasing by 52.9% and the efficiency of batch processing of 24 samples increasing by 66.2% .Moreover, the spiked recovery rate and relative standard deviationbothmeet the requirementsof thenational standard.

Key Words: food peroxide value; GB 5009.227—2023; determination eficiency; method improvement; detection equipment

1研究概述

1.1 研究背景与意义

过氧化值是衡量食品中油脂氧化酸败程度的重要指标,直接关系食品品质安全与消费者健康。(剩余5116字)