燃煤电厂烟气脱硫工艺对大气二氧化硫污染浓度影响研究

打开文本图片集
文章编号:1674-6139(2026)03-0084-05
中图分类号:X831文献标志码:B
Impact of Flue Gas Desulfurization Process in Coal -fired Power Plants on Atmospheric Sulfur Dioxide Pollution Concentration
Li Sailai1,Xiao Junchao’,Liu Xiongbo’,Cheng Zhiyuan²,Che You³ (1.Guoneng Changyuan Jingmen Power Generation Co.,Ltd.,Jingmen 448000,China; 2.State Power Environmental Protection Research Institute,Nanjing 21oooo,China; 3.Wuhan Longking Environmental Protection Engineering Co.,Ltd.,Wuhan 43O2O5,China)
Abstract:Inordertocontrolthedegreeofatmosphericpolutioncausedbycoal-firedpowerplants,afluegasdesulfurization processforcoal-firedpowerplantsisstudiedtoinvestgateitsimpactontheconcentrationofatmospericsulfurdioxidepolutiohe limestonegypsumwetfluegasdesulfurizationprocesswasusedtotreatthefuegasdesulfurizationofcoal-fredpowergenerationuitsin thesecondphaseexpansionprojectofapowerplantTheultravioletspectrophotometrymethodwasselectedtoetecttheconcentratioof sulfurdioxidepolutioninatmospericsamples.Theexperimentalresultsshowthatwhntheresidencetimeoffueasis6miutes,the flue gas desulfurization efficiency of coal-fired power plants remains above 98% .After flue gas desulfurization treatment,the atmospheric sulfur dioxide concentration decreased from 15.76μg/m3 and 15.59μg/m3 to 8.22μg/m3 and 8.16μg/m3 .The verification of flue gasdesulfurzationtechnologycanreducetheconcentrationofatmosphericsulfurdioxidepolution,reducethepolutionofcoalfired power plants to the atmosphere,significantly improve air quality and protect ecological balance.
Keywords:coal-fired powerplants;fluegasdesulfurization proces;sulfurdioxide;polutionconcentration;limestonegypsum
前言
燃煤电厂的二氧化硫排放量持续增加,使大气二氧化硫污染问题日益严峻。(剩余4389字)